The Basic Heated filter housing is a heated version designed for venting atmospheric or pressurized tanks in pharmaceutical environments. It meets the rigorous ASME VIII div.1 and ASME BPE standards, and like the Basic model, it completely eliminates loose parts inside to ensure product purity. Its 4” clamp connection facilitates assembly during maintenance, while its external heating system ensures product integrity. In addition, it incorporates a PT-100 temperature probe for precise and safe control. This housing is ideal for applications with purified water and fermentation in the food industry.
H | h | D | Inlet | Outlet | Condensate outlet | Heating | Sensor temperture | Integrity test |
---|---|---|---|---|---|---|---|---|
400 | 345 | 154 | 1” TC ASME BPE | Through connection body | Through connection body | 300W Electrical resistance. External heating insulaton | Sensor temperature type PT-100 to control the heating resistance temperature via PLC | No |
400 | 345 | 154 | 1-1/2” TC ASME BPE | Through connection body | Through connection body | 300W Electrical resistance. External heating insulaton | Sensor temperature type PT-100 to control the heating resistance temperature via PLC | No |
400 | 345 | 154 | 2” TC ASME BPE | Through connection body | Through connection body | 300W Electrical resistance. External heating insulaton | Sensor temperature type PT-100 to control the heating resistance temperature via PLC | No |